[Apr 22, 2024] RealVCE H19-338 Exam Practice Test Questions (Updated 217 Questions) [Q48-Q73]

Share

[Apr 22, 2024] RealVCE H19-338 Exam Practice Test Questions (Updated 217 Questions)

Pass Huawei H19-338 Exam Info and Free Practice Test


Huawei H19-338 exam is a comprehensive certification exam that requires candidates to have a deep understanding of storage technologies and their applications. H19-338 exam is conducted online and consists of multiple-choice questions. H19-338 exam is designed to test the candidates' knowledge and skills in various areas of storage solutions, including design, implementation, and management. Successful candidates are awarded the Huawei HCPP-Storage certification, which is recognized globally and can help them advance their careers in the field of storage solutions.

 

NEW QUESTION # 48
Which models support continuous cache mirroring? (Multiple choice)

  • A. 18500 V5
  • B. 5500V5
  • C. 5800 V5
  • D. 18800 V5
  • E. 6800 V5

Answer: A,D,E


NEW QUESTION # 49
Which statement about the Dorado's global garbage collection (GC) are correct? (Multiple choice)

  • A. Dorado supports intelligent adjustment of multiple GC levels based on the garbage percentage and CPU usage.
  • B. Global GC issues TRIM commands to trigger GC on SSDs.
  • C. When a conflict cocurs, user I/Os and metadata always have a higher priority than GC.

Answer: A,B,C


NEW QUESTION # 50
When SmartQoS is configured on Dorado V6 and the max, normalized IOPS (8 KB) is set to 10,000 for a target LUN, the maximum IOPS of the target LUN is ____ when 16 KB I/Os are written to and read from the target LUN.

  • A. 10,000 IOPS
  • B. Less than 10.000. The traffic limit is about 8.500 IOPS.

Answer: B


NEW QUESTION # 51
Which of the following are the strengths of the next-generation NetEngine AR routers?

  • A. Features multi-mode ZTP on-demand network orchestration; real-time fault alarms and 45+ visualized reports
  • B. Incorporates an industry-leading CPU+NP architecture, providing industry-lea ding L3 to L7 full-service efficient processing
  • C. Offers three times the industry average performance based on x86
  • D. Incorporates iPath (application-based intelligent traffic steering 8. optimization) and A-FEC {no frame freezing or artifacts even at a 20% packet loss rate)

Answer: A,B,C,D

Explanation:
Explanation
next-generation NetEngine AR routers are intelligent edge routers that provide comprehensive services for enterprises, such as WAN access, SD-WAN, VPN, voice, video, security, cloud interconnection, and IoT .
They have several strengths that differentiate them from other products in the market, such as:
Incorporating an industry-leading CPU+NP architecture, providing industry-leading L3 to L7 full-service efficient processing. The CPU+NP architecture combines the advantages of both CPU-based general-purpose processing and NP-based hardware acceleration, enabling high-performance processing of various services at different layers .
Incorporating iPath (application-based intelligent traffic steering & optimization) and A-FEC {no frame freezing or artifacts even at a 20% packet loss rate). iPath is a technology that intelligently steers traffic based on application types, quality requirements, link conditions, and policies, optimizing the user experience and resource utilization . A-FEC is a technology that enhances the error correction capability of video streams, ensuring smooth video transmission even under high packet loss scenarios .
Offering three times the industry average performance based on x86. The next-generation NetEngine AR routers use x86 processors that deliver high computing power and scalability, enabling them to support more services and users with lower power consumption .
Featuring multi-mode ZTP on-demand network orchestration; real-time fault alarms and 45+ visualized reports. The next-generation NetEngine AR routers support zero-touch provisioning (ZTP), which simplifies the network deployment and management process by automatically discovering, registering, configuring, and upgrading devices . They also support real-time fault alarms and 45+ visualized reports that provide comprehensive network monitoring and analysis capabilities .


NEW QUESTION # 52
Which reliability technologies are used in Huawei all-flash storage? (Multiple choice)

  • A. Bad block management
  • B. Wear leveling
  • C. RAID
  • D. Power failure protection

Answer: A,B,C


NEW QUESTION # 53
Which of the following are the common deployment modes used by the CloudCampus Solution to Implement plug-and-play of devices?

  • A. Registration query center deployment
  • B. DHCP Option 148
  • C. QR code scanning for deployment

Answer: A,B,C

Explanation:
Explanation
CloudCampus Solution is a cloud-based network management platform that provides plug-and-play of devices using three common deployment modes: QR code scanning for deployment, DHCP Option 148, and registration query center deployment . QR code scanning for deployment allows users to scan the QR code on the device label using a mobile app and automatically add the device to the cloud platform . DHCP Option 148 allows devices to obtain the cloud platform address from a DHCP server and automatically register with the cloud platform . Registration query center deployment allows devices to obtain the cloud platform address from a registration query center server and automatically register with the cloud platform . These deployment modes simplify the network configuration and management process and reduce the OPEX .


NEW QUESTION # 54
What technical features does Huawei's active-active (HyperMetro) solution provide? (Multiple choice)

  • A. cross-site bad block repair
  • B. HyperMetro for SAN and NAS
  • C. Visual management
  • D. Dual arbitration

Answer: A,B,C,D


NEW QUESTION # 55
The CloudEngine 16800 series switches support 4. 8.12. and 16 LPU slots.

  • A. True
  • B. False

Answer: B

Explanation:
Explanation
The CloudEngine 16800 series switches do not support 4, 8, 12, and 16 LPU slots. According to the CloudEngine 16800 Series Data Center Switches Datasheet, CloudEngine 16800 series switches support three models: CE16804 (4 LPU slots), CE16808 (8 LPU slots), and CE16816 (16 LPU slots). There is no model that supports 12 LPU slots.


NEW QUESTION # 56
HyperMetro quorum servers can be deployed on VMs.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 57
Huawei HyperMetro (active-active) solution supports non-disruptive capacity expansion.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 58
Which statements about OceanStor 100D are true? (Multiple choice)

  • A. It can be scaled out to a maximum of 4096 nodes.
  • B. It provides background data consistency checks.
  • C. It stores metadata in metadata nodes.
  • D. It employs a distributed cluster architecture.

Answer: A,B,C,D


NEW QUESTION # 59
In the headquarters-branch VXLAN Interconnection scenario, single-fabric networking is supported

  • A. True
  • B. False

Answer: B

Explanation:
Explanation
In the headquarters-branch VXLAN interconnection scenario, single-fabric networking is not supported.
According to the Huawei CloudCampus Solution Description, headquarters-branch VXLAN interconnection is a scenario that connects multiple campus networks over a WAN using VXLAN tunnels. In this scenario, each campus network forms an independent fabric network with its own controller and gateway devices.
Single-fabric networking is a scenario that connects multiple campus networks over a LAN usingVXLAN tunnels. In this scenario, all campus networks share the same fabric network with a unified controller and gateway devices.


NEW QUESTION # 60
Which of the following models supports expansion to up to 32 controllers?

  • A. OceanStor Dorado 300 V6
  • B. OceanStor Dorado 8000 V8
  • C. OceanStor Dorado 5000 V6
  • D. OceanStor Dorado 6000 V6

Answer: B


NEW QUESTION # 61
Which of the following are the three levels of SSD wear? (Multiple choice)

  • A. Mid-wear < 25%
  • B. Severe wear > 85%
  • C. Mid wear < 50%
  • D. Moderate wear: 50% <&&<85%

Answer: B,C,D


NEW QUESTION # 62
Among the Dorad o series storage systems, which o f the following back-end technologies provides the lowest theoretical latency?

  • A. SAS
  • B. PCIe
  • C. NVMe

Answer: C


NEW QUESTION # 63
Which disaster recovery solutions can Huawei Dorado V6 provide for customers? (Multiple Choice)

  • A. Sync. Storage replication solutions
  • B. Active-active solutions
  • C. DR-Star networking solutions
  • D. Async. Storage replication solutions
  • E. CDM solution with near real-time, continuous data protection

Answer: A,B,C,D,E


NEW QUESTION # 64
What is the IO model for Vdbench performance testing on the test of "Random Read and Write Performance (With Data Reduction)?

  • A. 8KB_70%Read_100%Random
  • B. 8KB_100%Read_70%Radom
  • C. 16KB_70%Read_100% Random

Answer: A


NEW QUESTION # 65
How many 1GE ports in a NE8000 F1A?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

Explanation:
Explanation
NE8000 F1A has 36 1GE ports. According to the NetEngine 8000 F1A Service Router Datasheet3, NE8000 F1A supports flexible combinations of up to 56 ports, including 36 x GE, 16 x 10GE, 2 x 40GE, and 2 x
100GE ports.


NEW QUESTION # 66
Which of the following chips are part of the Dorado V6 in addition to Dorado V3's self-developed chips? (Multiple choice)

  • A. AI chip
  • B. Multi-protocol interface chip
  • C. SSD controller chip
  • D. BMC chip
  • E. CPU chip

Answer: A,B,C,D,E


NEW QUESTION # 67
Which of the following statements are correct about the performance test of Dorado V6 mid-range product models on a Fiber Channel network? (Multiple choice)

  • A. Dorado V6 delivers similar performance when using RAID 5, RAID 6, and RAID-TP.
  • B. The test performance of a single LUN on Dorado V6 can reach over 80% of the system performance.
  • C. The performance when native multipathing software is used is similar to that when UltraPath is used.

Answer: A,B


NEW QUESTION # 68
What are the benefits of the multi-stream technology supported by Dorado? (Multiple choice)

  • A. No garbage collection overhand on SSDs.
  • B. Longer SSD service life
  • C. Less write application

Answer: A,B,C


NEW QUESTION # 69
In OceanStor V5, what protocols are supported by NAS? (Multiple choice)

  • A. HTTP
  • B. CIFS
  • C. FTP
  • D. NFS

Answer: A,B,C,D


NEW QUESTION # 70
Which arbitration mode does Huawei's active-active (HyperMetro) solution support? (Multiple choice)

  • A. Heartbeat
  • B. Static priority
  • C. Quorum server
  • D. Quorum disk

Answer: B,C


NEW QUESTION # 71
The redundancy design of key components of the S12700E series switches can achieves 99 999% reliability

  • A. False
  • B. True

Answer: B

Explanation:
Explanation
The redundancy design of key components of the S12700E series switches can achieve 99.999% reliability.
According to the CloudEngine S12700E Series Switches Datasheet, CloudEngine S12700E series switches support N+1 backup for MPUs, SFUs, CMUs, and power modules, as well as hot swapping for all components, ensuring high availability and reliability.


NEW QUESTION # 72
Which of the following are the end-to-end architecture optimization implemented by Dorado? (Multiple choice)

  • A. ROW-based full-stripe write and snapshot technology
  • B. RAID-TP
  • C. Global garbage collection
  • D. Multi-stream technology on SSDs.

Answer: A,C,D


NEW QUESTION # 73
......

Pass Your Huawei Exam with H19-338 Exam Dumps: https://pass4sures.realvce.com/H19-338-VCE-file.html